EXTERNAL PAGING

External Page (Figure 4-15, Figure 4-55)

Two external page zone/door box circuits are provided by each 2PGDAD installed. Each Door Box/external
page circuit also provides a dry relay contact. In programming, the external page speakers provided by the
2PGDAD modules are numbered 1-8 - the relays on the 2PGDAD modules are numbered 1-8. Refer to Pag-
ing, External in the Software Manual for additional details.
The 2PGDAD module can be used for talkback with External Page, as can a CO trunk port with the proper
external page equipment (ex: Valcom) - set Program 31-06-03 to "0" for talkback.

Installing an External Page System

1.
2.
3.
4.
5.
6.
7.
4-18 ◆ Section 4: Telephones and Optional Equipment
NOTE: A 2PGDAD circuit used for External Paging cannot also be used for an analog Door
Box.
Connecting to the 2PGDAD Module:
Make sure the jumper in the 2PGDAD module for the channel is set correctly. (Refer to Figure 4-4
JUMPER SETTINGS on page 4-3).
If a line cord was not previously connected to the 2PGDAD, complete Steps 3-6. Otherwise, skip to
Step 7.
Install a modular jack for each 2PGDAD module. For each module, run one-pair 24 AWG station
cable from the cross-connect block to a modular jack. Ground the unused pair(s).
Terminate the extension leads to GRN/RED of the modular jack. Terminate the unused leads to the
jack.
Install bridging clips as required.
Plug a modular line cord from the mod jack to the CN1 connector on the 2PGDAD module.
Connect the two-conductor station cable from the CN5 connectors within the 2PGDAD module to
the external relay/external page.
Refer to RELAYS (page 4-56) for further details on relays.