3 Setting Master/Slave Subracks
TN12AUX
CAUTION
Changing the subrack ID may interrupt services.
NOTE
•The TN12AUX board has two DIP switches. The value set by each switch can be 0 or 1 (in binary code).
•ID1–ID4 correspond to pins 1–4 on SW2 and ID5–ID8 correspond to pins 1–4 on SW1. ID1–ID5 are valid and ID6–
ID8 are reserved. Keep the ID6-ID8 settings shown in the following figures. From higher bits to lower bits are ID5–ID1,
which can be set to 32 combinations and the default value is 00000. The value 0 indicates the master subrack, and
the other values indicate slave subracks.
•When the DIP switch is toggled to ON, the value of the corresponding bit is set to 0.
(ID 1)
(ID 2)
(ID 3)
(ID 4)
(ID 5)
(ID 6)
(ID 7)
(ID 8)
9