HP 9000 300 Series Hardware Configuration Manual page 152

Hide thumbs Also See for 9000 300 Series:
Table of Contents

Advertisement

1.
Find the group of switches labeled SW1 by referring to Figure 10-12.
Switches 6 and 7 in this group determine the interrupt level.
2. Set the interrupt level to the desired value by referring to Table 10-24:
Table 10-24.
mterrupt Switch Switch
Level
6
7
3
0
0
4
0
1
5
1
0
6
1
1
Setting the Bus Address Switches.
1.
Find the group of switches labeled SW2 by referring to Figure 10-12.
Switches 2, 3, and 4 set the bus address.
2. Set the bus address switches as follows:
• first step
• second step.
Setting the Parity Switch.
1.
Find the group of switches labeled SW1 by referring to Figure 10-12. Switch
1 in this group is the PARity switch.
2. Set the parity switch as follows:
a. To enable parity checking, set the switch to
1.
b. To disable parity checking, set the switch to O.
Reinstalling the SCSI Card
Insert the SCSI interface, component side up, into its slot. Tighten the thumb
screws on the metal end plate until the end plate is flush with the back of the
controller.
Configuring Popular Accessory Cards
10-43