Ambient Conditions; Materials - ABB ACS800 Series Hardware Manual

Hide thumbs Also See for ACS800 Series:
Table of Contents

Advertisement

Ambient conditions

Installation site altitude
Air temperature
Relative humidity
Contamination levels
(IEC 60721-3-3, IEC 60721-3-
2, IEC 60721-3-1)
Atmospheric pressure
Vibration (IEC 60068-2)
Shock (IEC 60068-2-27)
Free fall

Materials

Drive enclosure
Package
Disposal
Environmental limits for the drive are given below. The drive is to be used in a heated,
indoor, controlled environment.
Operation
installed for stationary use
0 to 4000 m (13123 ft) above
sea level [above 1000 m
(3281 ft), see section
Derating]
Drives with option +Q967:
0 to 2000 (6562 ft)
-15 to +50 °C (5 to 122 °F).
No frost allowed. See section
Derating.
5 to 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the presence of
corrosive gases.
No conductive dust allowed.
Boards with coating:
Chemical gases: Class 3C2
Solid particles: Class 3S2
70 to 106 kPa
0.7 to 1.05 atmospheres
Max. 1 mm (0.04 in.)
(5 to 13.2 Hz),
2
2
max. 7 m/s
(23 ft/s
)
(13.2 to 100 Hz) sinusoidal
Not allowed
Not allowed
• PC/ABS 2.5 mm, colour NCS 1502-Y (RAL 9002 / PMS 420 C)
• hot-dip zinc coated steel sheet 1.5 to 2 mm, thickness of coating 100 micrometres
• extruded aluminium AlSi
Cardboard, plywood, PP bands (straps), PE plastic
The drive contains raw materials that should be recycled to preserve energy and natural
resources. The package materials are environmentally compatible and recyclable. All
metal parts can be recycled. The plastic parts can either be recycled or burned under
controlled circumstances, according to local regulations. Most recyclable parts are marked
with recycling marks.
If recycling is not feasible, all parts excluding electrolytic capacitors and printed circuit
boards can be landfilled. The DC capacitors (C1-1 to C1-x) contain electrolyte and the
printed circuit boards contain lead, both of which are classified as hazardous waste within
the EU. They must be removed and handled according to local regulations.
For further information on environmental aspects and more detailed recycling instructions,
please contact your local ABB distributor.
Storage
in the protective package
-
-40 to +70 °C
(-40 to +158 °F)
Max. 95%
Boards with coating:
Chemical gases: Class 1C2
Solid particles: Class 1S3
70 to 106 kPa
0.7 to 1.05 atmospheres
Max. 1 mm (0.04 in.)
(5 to 13.2 Hz),
2
2
max. 7 m/s
(23 ft/s
)
(13.2 to 100 Hz) sinusoidal
2
2
Max. 100 m/s
(330 ft./s
11 ms
250 mm (10 in.) for weight
under 100 kg (220 lb)
100 mm (4 in.) for weight
over 100 kg (220 lb)
Transportation
in the protective package
-
-40 to +70 °C
(-40 to +158 °F)
Max. 95%
Boards with coating:
Chemical gases: Class 2C2
Solid particles: Class 2S2
60 to 106 kPa
0.6 to 1.05 atmospheres
Max. 3.5 mm (0.14 in.)
(2 to 9 Hz),
2
max. 15 m/s
(49 ft/s
(9 to 200 Hz) sinusoidal
2
),
Max. 100 m/s
(330 ft./s
11 ms
250 mm (10 in.) for weight
under 100 kg (220 lb)
100 mm (4 in.) for weight
over 100 kg (220 lb)
Technical data