Before connecting the AC power cord, make sure:
The power switch at the left side of the KSU is turned OFF.
The power switch at the commercial AC power socket is turned OFF.
The AC plug fits the commercial AC power socket. The plug adapter is
necessary if it does not fit.
Type 3-pin Plug
KSU must have its own commercial AC power socket.
DO NOT POWER ON until KSU installation has been completed.
1.5

Trunk/Extension Cabling

1.5.1

General

The system provides RJ61 modular jacks for analogue/digital extension connections.
1.5.2

Precautions for Cabling

Do not wire the cable with an AC cable, computer, etc.
Do not run the cable near a high frequency generating device.
Use cable protectors in case the cables are run on the floor.
Aerial distribution wiring is not allowed.
Trunks must be installed with lightning protectors.
Do not install the Topaz Terminal in the SL1100 system, it does not work properly.
1.5.3

Trunk Cabling

Trunk cabling is required for the 4COIDB, 2BRIDB or 1PRIU PCBs.
Refer to INSTALLING THE EXPANSION INTERFACE CARDS for mounting and cabling 4COIDB, 2BRIDB
and 1PRIU PCBs.