DS1000/2000 Correspondence Course
System Programming
Program 1803 - Extension Line Access Assignments
142
DS1000/2000 Workbook
Use this program to assign the incoming and outgoing trunk access
for extensions.
1. Enter the programming mode.
2. 1803 +
HOLD
1803:LINE ACCESS
STATION #?nnn
3. Enter the number of the extension you want to program +
OR
Press
to select extension 300.
HOLD
1803: STA nnn
LINE NUMBER?n
The previously programmed value displays.
4. Enter the number of the trunk you want to program +
OR
Press
to select trunk 1.
HOLD
1803:STA:nnn LINE:n
nnnnnnnnnnn
The previously programmed value displays on the second line. The
first line of the display shows the extension and trunk you are pro-
gramming.
5. Enter the access option for the trunk selected (0 = No access, 1 = Incoming
only, 2 = Outgoing only, 3 = Full access) +
OR
Press
to leave the current unchanged.
VOL
1803:STA:nnn LINE:n
nnnnnnnnnnn
You see the options for the next consecutive trunk. The previously
programmed value displays.
6. Enter the access option for the currently selected trunk +
OR
Press
to select another trunk.
CONF
OR
Press
twice to select another extension port.
CONF
OR
Press
three times to exit the program.
CONF
HOLD
HOLD
VOL
VOL