DS1000/2000 Workbook
You must use PC Card P/N 85880 to back up and restore your side data.
The PC Card P/N 80051-V**.** has the system operating software and the
default database. The **.** denotes the level of the system software loaded
on PC Card P/N 80050. You cannot use this PC Card to store your customer
databases. Only the P/N 85880 can store customer databases. The number
of databases which can be stored on each card depends on your software
version.
U Slot, software 02.00.01 and above, has 16 database addresses: DB 00
to DB 15
Back Up Site Data
To use the PC Card to back up
site data:
1. Insert the PC Card into the
CPU.
2. Be sure the CPU mode switch
is set to RUN.
3. Enter the programming mode.
ICM + #*#* + 372000 +
HOLD
4. Dial 9906 + HOLD.
You see: START?
To quit program 9906
instead, dial N + HOLD.
5. Dial Y + HOLD.
You see:
9906: DATABASE NAME
6. Enter a name for the database
you want to save (up to 10 characters long).
Refer to the Keys for Entering Names table below if you need help
when entering names.
Skip this step if you want to save data in an address that already
has a name assigned.