DS1000/2000 Correspondence Course
DS2000 System Installation
106
DS1000/2000 Workbook
External Paging Relay Control
If the relay on the CPRU controls the External Paging relays, the following
programs must be set.
Program 0201: Door 1 Relay
Assign the Door 1 Relay for External Paging control, enter 2.
Program 0201: Page Zone (Door 1 Relay)
Enter the Page Zone (1-7) that should activate the Door 1 relay. Note
that Zone 1 and All Call Paging announcements broadcast from the
External Paging output.
Program 0201: Door 2 Relay
Assign the Door 2 Relay for External Paging control, enter 2.
Program 0201: Page Zone (Door 2 Relay)
Enter the Page Zone (1-7) that should activate the Door 2 relay. Note
that Zone 1 and All Call Paging announcements broadcast from the
External Paging output.
Door Box Relay Control
If the relay on the CPRU controls the strike for the door, the keyset that
answers the Door Box chimes can remotely open and close the strike.
0201: Door 1 Relay
Assign the Door 1 Relay for Door Box control, enter 1.
0201: Door 2 Relay
Assign the Door 2 Relay for Door Box control, enter 1.
1801: Relay Owner
Enter 1 to assign the CPRU PCB relay to the Door Box. Enter 0 to dis-
able the CPRU PCB relay for Door Box calls.
0401: Door Unlock Time
Enter the interval that the CPRU relay should remain closed after the
keyset user activates (closes) the relay. After this interval, the CPRU
automatically returns to its idle (open) state.