14. Installing the parts to Case
14-1. Install Magnet 59 to Magnet base 8 while making sure of the direction, then apply some instant glue between them.
(This step is the same procedure with Step 9-5.)
8
Magnet base
14-2. Install the unit reassembled in Step 14-1, then tighten Screw 102 (x1).
Torque: 43.2 cN•m (4.4 kgf•cm)
Apply Screw lock after tightening screws.
14-3. Install Lock plate 15 , then tighten Screw 102 (x1).
Torque: 43.2 cN•m (4.4 kgf•cm)
Apply Screw lock after tightening screws.
Note1: Keep Lock plate 15 pressing towards the direction of the arrow to secure with the screws. Refer to Figure of
Note1.
Note2: Verify the installation and removal of Safety wire ass'y 154 . Refer to Figure of Note2.
14-4. Place Rating label 29 to the specified position on Case 1 . (Rating label is not supplied as service part.)
Note3: Make sure of the direction to place.
154
Figure of Step 14-2
Figure of Step 14-1
Safety wire ass'y
Figure of Note2
The unit reassembled
in Step 14-1
102
Screw
2.6x4 mm (x1)
308
Screw lock
*Make sure of the
derection to place.
59
Magnet
(Fix using some instant glue.)
(View from the front to install)
29
Rating label
1
Case
Figure of
Steps 14-2 and 14-3
Keep pressing towards
the direction of the arrows
to secure with the screws.
–35–
*Make sure of the position of the mark
15
Lock plate
102
Screw 2.6x4 mm (x1)
308
Screw lock