INITiate Subsystem
The INITiate subsystem is used to control the initiation of the trigger.
Refer to the TRIGger and ABORt subsystems for related commands.
Continuous or Single Measurements
:INITiate:CONTinuous OFF|ON|0|1
:INITiate:CONTinuous?
Selects whether the trigger system is continuously initiated or not.
This command affects sweep if not in a measurement, and affects
trigger when in a measurement. A "measurement" refers to any of the
functions under the
sweep or single sweep operation when not in a measurement, and
continuous measurement or single measurement operation when in a
measurement.
When not in a measurement, this command does the following:
NOTE
• When ON at the completion of each sweep cycle, the sweep system
• When OFF, the sweep system remains in an "idle" state until
• The query returns 1 or 0 into the output buffer. 1 is returned when
When in a measurement, this command does the following:
• When ON at the completion of each trigger cycle, the trigger system
• When OFF, the trigger system remains in an "idle" state until
• The query returns 1 or 0 into the output buffer. 1 is returned when
Factory Preset: Continuous
Chapter 5
MEASURE
immediately initiates another sweep cycle.
CONTinuous is set to ON or an :INITiate[:IMMediate]
command is received. On receiving the :INITiate[:IMMediate]
command, it will go through a single sweep cycle, and then return to
the "idle" state.
there is continuous sweeping. 0 is returned when there is only a
single sweep.
immediately initiates another trigger cycle.
CONTinuous is set to ON or an :INITiate[:IMMediate]
command is received. On receiving the :INITiate[:IMMediate]
command, it will go through a single trigger cycle, and then return to
the "idle" state.
there is continuous triggering. 0 is returned when there is only a
single trigger.
key. This corresponds to continuous
Language Reference
INITiate Subsystem