15.
Heat exchanger
~
Isolate flow and return valves and drain
the boiler.
~
Remove condensate trap
(see page 40).
~
Remove fan assembly (see page 44).
15.1
~
Remove plastic nut (A) from the base
of the inner casing.
15.2
~
Remove return pipe (B) at the bottom
of heat exchanger.
15.3
~
Remove screw at the top of the heat
exchanger (C).
~Unscrew
the flow pipe (D).
15.4
~
Undo flue connection (E) from
sump (F).
~
Pull flue pipe up.
~
Remove the heat exchanger.