Wall Mounting Plate I Flue Opening - Bosch Worcester Greenstar CDi Conventional Series Instruction Manual

Wall hung rsf gas-fired condensing regular boiler for open vented and sealed central heating systems and indirect domestic hot water
Table of Contents

Advertisement

10mm0
-
-
min. 5 mm
~.
'
-
:;~-=---
. .
'
I
'
I
'
I
'
[]
~
0
J~D
6 720 614 039-05.1
0
0
~ORCESTER
INSTALLATION
&
SERVICING INSTRUCTIONS FOR WORCESTER BOSCH GREENSTAR 30CD,/40CD' Convent,onal
Bosch Group
6 720 614 556a (2007/07)
WALL MOUNTING PLATE
FLUE OPENING
CAUTION: Ensure there are no pipes, elec-
tric cables, damp proof courses or other
hazards before drilling.
SAFETY:
All relevant safety precautions must be under-
taken. Protective clothing, footwear, gloves and
safety goggles must be worn as appropriate.
FIXING THE POSITION OF THE WALL
MOUNTING PLATE:
The diagram opposite shows the relative
positions of the flue and the fixing of the wall
mounting plate, the mounting plate and
pipework mounting bracket.
~
Place the hanging bracket on the wall
mounting plate.
~
Place the wall mounting plate with hanging
bracket against the wall in the desired posi-
tion.
~
Mark 4 fixing points through
- one of the holes A
- one of the holes B
-hole C
-holeD
in the wall mounting plate/hanging bracket.
~
Drill the 4 holes for wall mounting plate, wall
hanging bracket and pipework mounting
bracket.
~
Secure wall mounting plate with hanging
bracket with 4 screws (supplied with the
boiler). Do not fully fasten the lower 2
screws.
FLUE OUTLET
~
Follow the diagram opposite to mark the
centre of the flue for rear outlet (1, & 2) or
for side outlet (2 & 3).
**
Note: increase this height by 52 mm for
every 1000 mm of horizontal length that the
flue outlet is away from the boiler.
~
For the 60/100 mm
0
flue make a 125 mm
diameter hole through the wall using a core
drill or similar.
For flues using an optional weather collar,
fitted from inside the building make a
150 mm
0
hole.
~
Clear away any debris.
FIXING THE PIPEWORK MOUNTING
BRACKET:
~
Mount the pipework mounting bracket on
the 2 lower screws and secure the screws.
WALL MOUNTING PLATE
FLUE OPENING