Failure Code [Dxe6Ka] Merge-Divider Ls Sol Discon - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

40 Troubleshooting

Failure code [DXE6KA] Merge-divider LS Sol Discon

User code
Failure code
DXE6KA
Contents of
• When merge-divider LS EPC solenoid was driven, disconnection was detected in circuit.
trouble
Action of
• None in particular (Since no current flows, solenoid does not operate).
controller
• If cause of failure disappears, system resets itself.
Problem that
appears on
• Single operation speed of work equipment and swing is high in lifting mode (L).
machine
• Drive current of merge-divider LS EPC solenoid can be checked with monitoring function.
Related infor-
(Code: 08001 merge-divider LS solenoid current)
mation
• Method of reproducing failure code: Turn starting switch ON.
Defective merge-divider LS
1
EPC solenoid (Internal dis-
connection)
Possible causes
Disconnection in wiring har-
and standard
ness (Disconnection in wiring
2
value in normal
or defective contact in con-
state
nector)
3 Defective pump controller
PC210, 230, 240-8
Merge-divider LS solenoid disconnection
Trouble
(Pump controller system)
Cause
a Prepare with starting switch OFF, then carry out troubleshooting
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between C02 (female) (89) –
V24 (female) (1)
Wiring harness between C02 (female) (115),
(117), (120) – V24 (female) (2)
a Prepare with starting switch OFF, then carry out troubleshooting
Between (89) – (115), (117),
Standard value in normal state/Remarks on troubleshooting
without turning starting switch ON.
V24 (male)
Between (1) – (2)
without turning starting switch ON.
without turning starting switch ON.
C02 (female)
(120)
UEN00243-01
1
Resistance
7 – 14 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resistance
7 – 14 z
23