Failure Code [Ca452] Rail Press Sensor Low Error - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00241-01

Failure code [CA452] Rail Press Sensor Low Error

User code
Failure code
E11
Contents of
• There is low voltage in signal circuit of common rail pressure sensor.
trouble
Action of
• Limits output and continues operation.
controller
Problem that
• Engine does not start.
appears on
• Engine speed or output lowers.
machine
• Signal voltage of common rail pressure sensor can be checked with monitoring function.
Related infor-
(Code: 36401 Common rail pressure sensor voltage)
mation
• Method of reproducing failure code: Turn starting switch ON.
Defective sensor power sup-
1
ply 2 system
Defective common rail pres-
2
sure sensor
Ground fault in wiring har-
3
ness (Short circuit with GND
circuit)
Possible causes
and standard
value in normal
state
Short circuit in wiring har-
4
ness (with another wiring
harness)
Defective wiring harness
5
connector
6 Defective engine controller
24
Trouble
CA452
Cause
Common rail pressure sensor low error
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
If failure code [CA187] is also displayed, carry out troubleshooting
for it first.
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
FUEL RAIL PRESS
Between (3) – (1)
Voltage is measured with wiring harness connected. Accordingly, if
voltage is abnormal, check wiring harness and controller, too, for
another cause of trouble, and then judge.
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
Wiring harness between CE01 (female) (25)
– FUEL RAIL PRESS (female) (2)
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between CE01 (female) (25)
– FUEL RAIL PRESS (female) (2) and
between CE01 (female) (47) – JC02 – FUEL
RAIL PRESS (female) (1)
Connecting parts between common rail pressure sensor – engine
wiring harness – engine controller may be defective. Check them
directly.
• Looseness of connector, breakage of lock, or breakage of seal
• Corrosion, bend, breakage, push-in, or expansion of pin
• Moisture or dirt in connector or defective insulation
a Prepare with starting switch OFF, then turn starting switch ON
and carry out troubleshooting.
CE01
Between (37) – (47)
40 Troubleshooting
Power supply
4.75 – 5.25 V
Resis-
tance
Resis-
tance
Power supply
4.75 – 5.25 V
PC210, 230, 240-8
1
Voltage
Min. 100
kz
Min. 100
kz
Voltage

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents