Failure Code [Ab00Ke] Charge Voltage Low - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00240-01

Failure code [AB00KE] Charge Voltage Low

User code
Failure code
AB00KE
Contents of
• While engine is running, signal circuit of alternator detected low charge voltage (below 7.8 V).
trouble
Action of
• Displays charge level monitor on machine monitor.
machine monitor
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
• If machine is operated as it is, battery may not be charged.
machine
Related infor-
• Signal voltage of alternator can be checked with monitoring function. (Code: 04300 Charge voltage)
mation
• Method of reproducing failure code: Start engine.
Possible causes
Defective charge of alterna-
1
and standard
tor (when system is normal)
value in normal
state
Defective charge level moni-
2
tor
18
Charge voltage low
Trouble
(Machine monitor system)
Cause
a Prepare with starting switch OFF, then start engine and carry out
Between (1) – chas-
If cause 1 is not detected, charge level monitor system may be
defective. Carry out troubleshooting for "E-7 Caution item flashes
while engine is running" in E-mode.
Standard value in normal state/Remarks on troubleshooting
troubleshooting.
E12 (male)
Engine speed
Min. medium speed
sis ground
40 Troubleshooting
1
Voltage
27.5 – 29.5 V
PC210, 230, 240-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents