Failure Code [Dw43Ka] Travel Speed Sol Discon - Komatsu PC210-8 Shop Manual

Hydraulic excavator
Hide thumbs Also See for PC210-8:
Table of Contents

Advertisement

UEN00242-01

Failure code [DW43KA] Travel Speed Sol Discon

User code
Failure code
DW43KA
Contents of
• When output to travel speed shifting solenoid was turned ON, disconnection was detected in circuit.
trouble
Action of
• None in particular. (Since no current flows, solenoid does not operate.)
controller
• If cause of failure disappears, system resets itself.
• PC210: Speed is low at High travel speed position (Machine monitor is set to High but actual speed
Problem that
is about Middle).
appears on
• PC240: Speed is low at High and Middle travel speed position (Machine monitor is set to High or
machine
Middle but actual speed is about Low).
• Operating condition of travel speed shifting solenoid can be checked with monitoring function.
Related infor-
(Code: 02300: Solenoid 1)
mation
• Method of reproducing failure code: Start engine + Set travel speed to High + Operate travel lever.
Defective travel speed shift-
1
ing solenoid (Internal discon-
nection)
Possible causes
Disconnection in wiring har-
and standard
ness (Disconnection in wiring
2
value in normal
or defective contact in con-
state
nector)
3 Defective pump controller
30
Travel speed solenoid system disconnection
Trouble
(Pump controller system)
Cause
a Prepare with starting switch OFF, then carry out troubleshooting
a Prepare with starting switch OFF, then carry out troubleshooting
Wiring harness between C02 (female) (87) –
V04 (female) (1)
Wiring harness between C02 (female) (115),
(117), (120) – V04 (female) (2)
a Prepare with starting switch OFF, then carry out troubleshooting
Between (87) – (115), (117),
Standard value in normal state/Remarks on troubleshooting
without turning starting switch ON.
V04 (male)
Between (1) – (2)
without turning starting switch ON.
without turning starting switch ON.
C01 (female)
(120)
40 Troubleshooting
1
Resistance
20 – 60 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resistance
20 – 60 z
PC210, 230, 240-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc240lc-8Pc240nlc-8Pc210nlc-8Pc210lc-8Pc230nhd-8

Table of Contents