SLIGHT VIBRATION SUPPRESSION CONTROL
This function suppresses the variation of the pulses generated at each servo motor stop.
8.1
Restrictions on the slight vibration suppression
control
• The slight vibration suppression control is enabled in the position mode.
• The slight vibration suppression control is enabled when [Pr. PA08.0 Gain adjustment mode] is set to "3" (manual mode).
8.2
Settings of the slight vibration suppression
control
When using the slight vibration suppression control, set the following servo parameters.
Servo parameter
PB24.0
8.3

Operation of slight vibration suppression control

The slight vibration suppression control function changes the gain from the rising edge position of INP (In-position) OFF to ON
to suppress the variation of the pulses generated at a servo motor stop. When the slight vibration suppression control is
enabled, the gain is calculated automatically in the servo amplifier. If the droop pulses exceed the in-position range while
driving the servo motor, the gain changes back to the original gain.
INP range
ON
INP signal
OFF
Gain
8 SLIGHT VIBRATION SUPPRESSION CONTROL
92

8.1 Restrictions on the slight vibration suppression control

Description
Slight vibration suppression control selection
0: Disabled
1: Enabled
Servo motor speed
Original gain
Droop pulses
Gain in slight vibration suppression control
Servo motor speed
Original gain