Item
Thermal
shock
Salty fog test
Sine
vibration
Shock test
Issue 09 (2017-12-15)
Test Condition
Low temperature: –40º C
High temperature: 85º C
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100 cycles;
15 min+15 min/cycle
Temperature: 35° C
Density of the NaCl
solution: 5%±1%
Operation mode: no
power, no package
Test duration:
Spraying interval: 8 h
Exposing period after
removing the salty fog
environment: 16 h
Frequency range: 5 Hz to
200 Hz
Acceleration: 1 Grms
Frequency scan rate: 0.5
oct/min
Operation mode: working
with service connected
Test duration: 3 axial
directions. 2 h for each
axial direction.
Half-sine wave shock
Peak acceleration: 30
Grms
Shock duration: 11 ms
Operation mode: working
with service connected
Test duration: 6 axial
directions. 3 shocks for
each axial direction.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Standard
Sample size
JESD22-A1
3 pcs/group
06-B
JESD22-A1
3 pcs/group
07-B
JESD22-B1
3 pcs/group
03-B
JESD-B104
3 pcs/group
-C
Results
Visual inspection:
ok
Function test: ok
RF specification: ok
Visual inspection:
ok
Function test: ok
RF specification: ok
Visual inspection:
ok
Function test: ok
RF specification: ok
Visual inspection:
ok
Function test: ok
RF specification: ok