Representation In The Project Navigator; Assigning Path Object Parameters/Default Values - Siemens SIMOTION Function Manual

Motion control to path interpolation
Hide thumbs Also See for SIMOTION:
Table of Contents

Advertisement

Configuring the Path Object

3.4 Representation in the project navigator

3.4
Representation in the project navigator
The path object appears in the project navigator at the same level as the Axis and Cam
technology objects. Links symbolize the connection to path axes or a positioning axis for
path-synchronous motion.
Figure 3-4
3.5

Assigning path object parameters/default values

● In the project navigator, double-click Defaults under the object.
Dynamic response parameters
You specify the path velocity, the velocity profile, and the acceleration/deceleration and jerk
on the Dynamic response tab.
86
Project with path interpolation in the project navigator
In this window, you define the substitute values (defaults) for calling the path object
(_movePath...(), _stopPath(), etc.).
TO Path Interpolation
Function Manual, 11/2010

Hide quick links: