AF-650 GP 230V 15 HP
Cable
length [m]
30
100
150
AF-650 GP 230V 20 HP
Cable
length [m]
4
36
136
150
AF-650 GP 230V 25 HP
Cable
length [m]
36
136
150
AF-650 GP 230V 30 HP
Cable
length [m]
15
50
150
AF-650 GP 230V 40 HP
Cable
length [m]
30
100
150
AF-650 GP 230V 50 HP
Cable
length [m]
30
100
150
AF-650 GP 460V 5 HP
Cable
length [m]
5
50
150
78
Rise time
Mains
voltage [V]
[μsec]
240
0.556
240
0.592
240
0.708
Mains
Rise time
voltage [V]
[μsec]
240
0.244
240
0.568
240
0.720
Rise time
Mains
voltage [V]
[μsec]
240
0.244
240
0.568
240
0.720
Mains
Rise time
voltage [V]
[μsec]
240
0.194
240
0.252
240
0.488
Rise time
Mains
voltage [V]
[μsec]
240
0.300
240
0.536
240
0.776
Rise time
Mains
voltage [V]
[μsec]
240
0.300
240
0.536
240
0.776
Rise time
Mains
voltage [V]
[μsec]
480
0.172
480
0.310
480
0.370
du/dt
Upeak
[kV]
[kV/μsec]
0.650
0.935
0.594
0.802
0.587
0.663
Upeak
du/dt
[kV]
[kV/μsec]
0.608
1.993
0.580
0.816
0.574
0.637
du/dt
Upeak
[kV]
[kV/μsec]
0.608
1.993
0.580
0.816
0.574
0.637
Upeak
du/dt
[kV]
[kV/μsec]
0.626
2.581
0.574
1.822
0.538
0.882
du/dt
Upeak
[kV]
[kV/μsec]
0.598
1.594
0.566
0.844
0.546
0.562
du/dt
Upeak
[kV]
[kV/μsec]
0.598
1.594
0.566
0.844
0.546
0.562
du/dt
Upeak
[kV]
[kV/μsec]
0.890
4.156
2.564
1.190
1.770
AF-650 GP Design Guide