DSS User Interface
4–6
4.3

DSS monitor

Current parameter
Current parameter
value.
Single parameter
The DSS monitor offers direct access to all parameters stored in the drive.
You may:
D edit parameters
D save a list of several parameters as parameter file (*.asd).
D transmit parameters to the drive.
.
If parameters are changed directly on the inverter keyboard while the
DSS is active, the DSS must first be reset afterwards. Click on
Start the "Monitor"
L
D menu sequence DISPLAY " MONITOR, or
D by clicking on the
Read all parameters
from an *.asd file and
show them in a list.
1. Click on the "Ident No." field
2. Enter the parameter number to be edited.
Structure of the parameter number:
A-[Parameter set]number
The following syntax options may be used:
D complete, e.g. "A-0-0012"
D simplified, e.g. "a12" , "a-12", "a-0-12" or "12" , if "Ident number prefix
automatic" has been activated in the menu EXTRAS " SETTINGS "
GENERAL (= default setting).
command button.
1070 066 028-101 (01.05) GB
.
Read current pa-
rameter from the
drive
Transfer current pa-
rameters to the
drive. Parameter
changes become
immediately active.
Read all parame-
ters from the drive
and save as *.asd
file.