Conducted Rf Measurement; Test Environment; Test Standards; Conducted Rx Sensitivity And Tx Power - Huawei MU609 Hardware Manual

Hspa lga module
Hide thumbs Also See for MU609:
Table of Contents

Advertisement

HUAWEI MU609 HSPA LGA Module
Hardware Guide

4.3 Conducted RF Measurement

4.3.1 Test Environment

Test instrument
Power supply
RF cable for testing

4.3.2 Test Standards

Huawei modules meet 3GPP test standards. Each module passes strict tests at the
factory and thus the quality of the modules is guaranteed.

4.4 Conducted Rx Sensitivity and Tx Power

4.4.1 Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU609.
Table 4-2 MU609 conducted Rx sensitivity (unit: dBm)
Band
GSM 850
GSM 900
DCS 1800
PCS 1900
WCDMA Band 1 Main RX
WCDMA Band 2 Main RX
WCDMA Band 5 Main RX
WCDMA Band 8 Main RX
Issue 04 (2016-12-12)
R&S CMU200
KEITHLEY 2306
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29 cm
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Typical Value
–110 dBm
–110 dBm
–109.5 dBm
–109 dBm
–111 dBm
–110 dBm
–111 dBm
–112 dBm
RF Specifications
Note
BER Class II < 2.44%
BER Class II < 2.44%
BER Class II < 2.44%
BER Class II < 2.44%
BER < 0.1%
BER < 0.1%
BER < 0.1%
BER < 0.1%
45