Huawei MU609 Hardware Manual page 60

Hspa lga module
Hide thumbs Also See for MU609:
Table of Contents

Advertisement

HUAWEI MU609 HSPA LGA Module
Hardware Guide
Item
Drop test
Life
High temperature
operating life
High temperature
& high humidity
Temperature
cycle-Non
operating
ESD
HBM (Human
Body Model)
ESD with DVK (or
embedded in the
host)
Groups ≥ 2
Issue 04 (2016-12-12)
Test Condition
0.8 m in height. Drop the
module on the marble
terrace with one surface
facing downwards, six
surfaces should be
tested.
Operation mode: no
power, no package
Temperature: 70º C
Operation mode: working
with service connected
Test duration: 168 h, 336
h, 500 h, 1000 h for
inspection point
High temperature: 85º C
Humidity: 85%
Operation mode: powered
on and no working
Test duration: 168 h, 336
h, 500 h, 1000 h for
inspection point
High temperature: 85º C
Low temperature: –40º C
Temperature change
slope: 6º C/min
Operation mode: no
power
Test duration: 168 h,
336 h, 500 h, 1000 h for
inspection point
1 kV (Class 1 B)
Operation mode: no
power
Contact Voltage: ± 2 kV,
±4 kV
Air Voltage : ±2 kV, ±4 kV,
±8 kV
Operation mode: working
with service connected
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Electrical and Reliability Features
Standard
Sample
size
IEC6006
3 pcs/group
8-2-32
JESD22-
50
A108-B
pcs/group
JESD22-
50
A110-B
pcs/group
JESD22-
50
A104-C
pcs/group
JESD22-
3 pcs/group
A114-D
IEC6100
2 pcs
0-4-2
Results
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Cross section: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Cross section: ok
Visual inspection: ok
Function test: ok
RF specification: ok
Visual inspection: ok
Function test: ok
RF specification: ok