Conducted Rf Measurement; Test Environment; Test Standards; Conducted Rx Sensitivity And Tx Power - Huawei MU736 Hardware Manual

Hide thumbs Also See for MU736:
Table of Contents

Advertisement

HUAWEI MU736 HSPA+ M.2 Module
Hardware Guide

4.3 Conducted RF Measurement

4.3.1 Test Environment

Test instrument
Power supply
RF cable for testing
Murata coaxial cable

4.3.2 Test Standards

Huawei modules meet 3GPP TS 51.010-1 and 3GPP TS 34.121-1 test standards.
Each module passes strict tests at the factory and thus the quality of the modules is
guaranteed.

4.4 Conducted Rx Sensitivity and Tx Power

4.4.1 Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU736.
The 3GPP Protocol Claim column in Table 4-2 lists the required minimum values,
and the Test Value column lists the tested values of MU736.
Table 4-2 MU736 conducted Rx sensitivity (Unit: dBm)
Item
GSM850
GSM900
Issue 05 (2014-01-14)
R&S CMU200, Agilent E5515C, GSS6700
Keithley 2303, Agilent 66319
Rosenberger Precision Microwave Cable
MXHP32HP1000
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
GMSK (CS1, BLER <
10%)
8PSK (MCS5, BLER <
10%)
GMSK (CS1, BLER <
10%)
8PSK (MCS5, BLER <
10%)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3GPP Protocol
MU736 Test Value (dBm)
Claim (dBm)
Min.
< –102
-
< –98
-
< –102
-
< –98
-
RF Specifications
Typ.
Max.
–108
-
–101
-
–108
-
–101
-
44