• When exchanging data with ASCII codes
Command format (external device  RJ71EN71)
Subheader
36H
32H
30H
30H
(H)
-
-
(L)
31H
32H
33H
34H
Random access buffer
Physical address
Logical address
(H)
(L)
20000
12H
34H
20001
56H
78H
20002
9AH
BCH
20009
9AH
BCH
26143
Response format (RJ71EN71  external device)
Subheader
End code
45H
32H
30H
30H
Start address
(H)
-
-
(L)
(H)
00H
00H
00H
00H
00H
Text (20 words)
(H)
-
-
(L)
(H)
35H
36H
37H
38H
39H
ASCII-binary conversion
0
1
2
9
(10 words)
6143
Data length
-
-
(L)
00H
00H
41H
-
-
(L)
41H
42H
43H
1.6 Communications Using the Random Access Buffer
(H)
-
-
(L)
39H
41H
42H
43H