Mitsubishi Electric MELSEC iQ-R Series User Manual page 68

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

When R mode is used
■Un\G0 to Un\G511
Address
Decimal (Hexadecimal)
CH1
CH2
CH3
0
16
32
(0H)
(10H)
(20H)
1
17
33
(1H)
(11H)
(21H)
2
18
34
(2H)
(12H)
(22H)
3
19
35
(3H)
(13H)
(23H)
4
20
36
(4H)
(14H)
(24H)
5
21
37
(5H)
(15H)
(25H)
6
22
38
(6H)
(16H)
(26H)
7
23
39
(7H)
(17H)
(27H)
8
24
40
(8H)
(18H)
(28H)
9
25
41
(9H)
(19H)
(29H)
10
26
42
(AH)
(1AH)
(2AH)
11
27
43
(BH)
(1BH)
(2BH)
to
to
to
15
31
47
(FH)
(1FH)
(2FH)
128
160
192
(80H)
(A0H)
(C0H)
129
161
193
(81H)
(A1H)
(C1H)
130
162
194
(82H)
(A2H)
(C2H)
131
163
195
(83H)
(A3H)
(C3H)
132
164
196
(84H)
(A4H)
(C4H)
133
165
197
(85H)
(A5H)
(C5H)
134
166
198
(86H)
(A6H)
(C6H)
135
167
199
(87H)
(A7H)
(C7H)
136
168
200
(88H)
(A8H)
(C8H)
137
169
201
(89H)
(A9H)
(C9H)
138
170
202
(8AH)
(AAH)
(CAH)
139
171
203
(8BH)
(ABH)
(CBH)
140
172
204
(8CH)
(ACH)
(CCH)
141
173
205
(8DH)
(ADH)
(CDH)
APPX
66
Appendix 3 Buffer Memory Areas
CH4
CH5
CH6
CH7
48
64
80
96
(30H)
(40H)
(50H)
(60H)
49
65
81
97
(31H)
(41H)
(51H)
(61H)
50
66
82
98
(32H)
(42H)
(52H)
(62H)
51
67
83
99
(33H)
(43H)
(53H)
(63H)
52
68
84
100
(34H)
(44H)
(54H)
(64H)
53
69
85
101
(35H)
(45H)
(55H)
(65H)
54
70
86
102
(36H)
(46H)
(56H)
(66H)
55
71
87
103
(37H)
(47H)
(57H)
(67H)
56
72
88
104
(38H)
(48H)
(58H)
(68H)
57
73
89
105
(39H)
(49H)
(59H)
(69H)
58
74
90
106
(3AH)
(4AH)
(5AH)
(6AH)
59
75
91
107
(3BH)
(4BH)
(5BH)
(6BH)
to
to
to
to
63
79
95
111
(3FH)
(4FH)
(5FH)
(6FH)
224
256
288
320
(E0H)
(100H)
(120H)
(140H)
225
257
289
321
(E1H)
(101H)
(121H)
(141H)
226
258
290
322
(E2H)
(102H)
(122H)
(142H)
227
259
291
323
(E3H)
(103H)
(123H)
(143H)
228
260
292
324
(E4H)
(104H)
(124H)
(144H)
229
261
293
325
(E5H)
(105H)
(125H)
(145H)
230
262
294
326
(E6H)
(106H)
(126H)
(146H)
231
263
295
327
(E7H)
(107H)
(127H)
(147H)
232
264
296
328
(E8H)
(108H)
(128H)
(148H)
233
265
297
329
(E9H)
(109H)
(129H)
(149H)
234
266
298
330
(EAH)
(10AH)
(12AH)
(14AH)
235
267
299
331
(EBH)
(10BH)
(12BH)
(14BH)
236
268
300
332
(ECH)
(10CH)
(12CH)
(14CH)
237
269
301
333
(EDH)
(10DH)
(12DH)
(14DH)
Name
CH8
112
CH Sampling pulse number
(70H)
113
System area
(71H)
114
CH Accumulating count value
(72H)
(L)
115
CH Accumulating count value
(73H)
(H)
116
CH Input pulse value (L)
(74H)
117
CH Input pulse value (H)
(75H)
118
CH Overflow detection flag
(76H)
119
CH Carry over detection flag
(77H)
120
CH Warning output flag
(78H)
121
CH Error code
(79H)
122
CH Alarm code
(7AH)
123
System area
(7BH)
to
127
(7FH)
352
CH Comparison output
(160H)
selection
353
System area
(161H)
354
CH Comparison output setting
(162H)
value (L)
355
CH Comparison output setting
(163H)
value (H)
356
CH Moving average
(164H)
processing selection
357
CH Number of moving
(165H)
average processing
358
CH Pre-scale function
(166H)
selection
359
CH Pre-scale setting value
(167H)
360
CH Warning output selection
(168H)
361
CH Warning output setting
(169H)
value upper/upper limit
362
CH Warning output setting
(16AH)
value upper/lower limit
363
CH Warning output setting
(16BH)
value lower/upper limit
364
CH Warning output setting
(16CH)
value lower/lower limit
365
CH Count cycle change
(16DH)
function selection
Default
Data type
Auto
value
refresh
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Monitor
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting

Advertisement

Table of Contents
loading

Table of Contents