CH1 Accumulating counter comparison flag
This signal corresponding to the relevant channel turns on when 'CH1 Accumulating count value' (Un\G2, Un\G3) reaches or
exceeds the setting value of 'CH1 Comparison output setting value' (Un\G130, Un\G131).
Cv
Comparison output
setting value
'CH1 Accumulating
counter comparison
flag' (X10)
'CH1 Comparison signal
reset request' (Y10)
Performed by the pulse input module
Performed by a program
Cv: Accumulating count value
t:
Time
(1) The accumulating count value is compared in the cycle set by 'CH1 Count cycle setting value' (Un\G142).
■Turning off 'CH1 Accumulating counter comparison flag' (X10)
Turning on and off 'CH1 Comparison signal reset request' (Y10) turns off this signal. Once this signal has turned off, it will not
turn on until 'CH1 Accumulating count value' (Un\G2, Un\G3) is reset and reaches the setting value of 'CH1 Comparison
output setting value' (Un\G130, Un\G131) again.
■Device numbers
The following shows the device numbers of this input signal.
Signal name
CH Accumulating counter comparison flag