Mains chokes

What this chapter contains

This chapter describes how to select and install mains chokes for the ACSM1-04.
The chapter also contains the relevant technical data.

When is a mains choke required?

The ACSM1-04 does not necessarily require a mains choke for operation; the need
for a choke should be determined on a case-by-case basis. Mains chokes are
typically used to
• reduce harmonics in the input current
• achieve a reduction in the r.m.s. input current
• reduce supply disturbance and low-frequency interference
• increase the allowed DC bus continuous power
• ensure even current distribution in common DC configurations (see page 56).

Selection table

ACSM1-04xx...
The mains chokes are protected to IP20. Refer to page
sizes and tightening torques.
Mains chokes for ACSM1-04
Drive type
Type
-02A5-4
-03A0-4
CHK-01
-04A0-4
-05A0-4
CHK-02
-07A0-4
-09A5-4
CHK-03
-012A-4
-016A-4
CHK-04
-024A-4
CHK-05
-031A-4
-040A-4
CHK-06
-046A-4
-060A-4
CHK-07
-073A-4
CHK-08
-090A-4
Inductance
µH
6370
4610
2700
1475
1130
700
450
355
PDM-00425726
105
for dimensions, wire
Mains chokes