Result
Write access for SNMPv1 and SNMPv2 PDUs is enabled.
Further notes
You block write access for SNMPv1 and SNMPv2 PDUs with the
command.
7.4.2.20

snmp user

Description
With this command, you configure the details of an SNMP user.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp user <UserName>[auth{md5|sha} <passwd>[priv DES<passwd>]]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
UserName
auth
passwd
priv DES
passwd
Storage type
If optional parameters are not specified when configuring an SNMP user, the defaults values
apply.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Name of the user
specifies that authentication takes
place and which algorithm is used
Password for authentication
specifies that there is encryption
Value for the password of the encryp-
tion
specifies whether the settings remain
following a restart:
Network protocols
7.4 SNMP
snmp v1-v2 readonly
Range of values / note
max. 32 characters
(Message Digest 5)
md5
(Secure Hash Algorithm)
sha
Default: No authentication
max. 32 characters
-
Default: no encryption
max. 32 characters
(volatile):
volatile
The default settings are used
after a restart
(non-volatile):
nonvolatile
The saved settings are used
after a restart