No Snmp Notify - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Network protocols
7.4 SNMP
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]]
The parameters have the following meaning:
Parameter
NotifyName
tag
TagName
Type
Storage type
Result
The details of the SNMP notifications are configured.
Further notes
You delete the details of an SNMP group with the
You display the configured SNMP notifications with the
You display the configured SNMP target addresses with the
command.
7.4.2.13

no snmp notify

Description
With this command, you delete the details of the SNMP notifications.
342
Description
Name of the SNMP notification
Keyword for a target key
Name of the target key
Type of the SNMP notification
specifies whether the settings remain
following a restart:
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
max. 32 characters
-
max. 32 characters
Trap
generates a trap
Inform
generates a log entry or sends
an entry to the log server
volatile
The settings are lost after a
restart
nonvolatile
The settings are retained after
a restart
command.
no snmp notify
show snmp notif
show snmp targetaddr
Configuration Manual, 10/2015, C79000-G8976-C351-05
(volatile):
(non-volatile):
command.