9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Value Range
Max. 7 digits (consisting of 0–9, *, and #)
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Voice/FAX
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Connection
Indicates the port status. To change the status of the port, click the desired cell in the column, and then select
INS or OUS for the port.
This option is only available in On-line mode.
Value Range
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not communicating with the network.
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
IP Codec Priority—1st, 2nd, 3rd
Specifies the priority of the codecs to be used. None is only available for 2nd and 3rd priorities.
Value Range
G.711A, G.711Mu, G.729A, None
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
Packet Sampling Time (G.711A)
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Value Range
20 ms, 30 ms, 40 ms, 50 ms, 60 ms
Maintenance Console Location
9.11 PBX Configuration—[1-1] Configuration—Slot—V-SIPGW—Port Property
288