1.2.1 Starting Web Maintenance Console
For details regarding the above settings, refer to your Web browser's documentation.
PC Specifications (for programming)
The following are recommended specifications for PCs used for programming. For details about programming
in Off-line mode, see 1.2.2 PC Programming Using Off-line Mode.
CPU
RAM
Hard Disk
Copyright for MD5
This software uses the Source Code of RSA Data Security, Inc. described in the RFC1321 (MD5
Message-Digest Algorithm).
Copyright (C) 1991-2, RSA Data Security, Inc. Created 1991. All rights reserved.
Licence to copy and use this software is granted provided that it is identified as the "RSA Data Security, Inc.
MD5 Message-Digest Algorithm" in all material mentioning or referencing this software or this function.
Licence is also granted to make and use derivative works provided that such works are identified as "derived
from the RSA Data Security, Inc. MD5 Message-Digest Algorithm" in all material mentioning or referencing the
derived work.
RSA Data Security, Inc. makes no representations concerning either the merchantability of this software or
the suitability of this software for any particular purpose. It is provided "as is" without express or implied warranty
of any kind.
These notices must be retained in any copies of any part of this documentation and/or software.
PC Connection (On-line Mode)
To connect to Web Maintenance Console in On-line mode, both the PC and the PBX must be connected. The
connection can be made through a local area network (LAN), a virtual private network (VPN), or over the
Internet. A PC can also be connected directly to the maintenance port of the PBX.
Note
When connecting to Web Maintenance Console over the Internet, the use of an encrypted
communication method, such as SSL, is strongly recommended. For details, contact your network's
administrator.
Connecting to Web Maintenance Console (On-line Mode)
Below is the procedure for connecting to Web Maintenance Console to programme in On-line mode:
1.
Connect the PC to the PBX:
Connect the PBX to a PC with the MNT port and access the PBX directly from the PC.
Connect the PBX to a network with the LAN port and access the PBX from a PC in your LAN or VPN.
Connect the PBX to a network with the LAN port and access the PBX from a PC using an Internet
connection.