Check Ip Network Connection - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Check IP network connection

If the Management port indicators are illuminated (for a network using out-of-band
management) or the Data port indicators are illuminated (for a network using in-
band management) but the IP address of the CMU is unknown, continue at
Entering recovery mode
configuration.
If the IP address of the CMU is known, send a sequence of ICMP Echo Request
packets to the CMU management agent using the Ping program at the command
line interface of the management PC or workstation.
If the CMU responds then the command line will appear similar to this:
C:\ping 169.254.1.1
Pinging 169.254.1.1 with 32 bytes of data:
Reply from 169.254.1.1: bytes=32 time=1ms TTL=64
Reply from 169.254.1.1: bytes=32 time<1ms TTL=64
Reply from 169.254.1.1: bytes=32 time<1ms TTL=64
Reply from 169.254.1.1: bytes=32 time<1ms TTL=64
Ping statistics for 169.254.1.1:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 1 ms, Average = 0ms
If the CMU fails to respond then the command line will appear similar to this:
C:\ping 169.254.1.1
Pinging 169.254.1.1 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Request timed out.
Ping statistics for 169.254.1.1:
Packets: Sent = 4, Received = 0, Lost = 4 (100% loss),
Check the Ping response and take action as described in
phn-1478_005v000
Apr 2010
on page 7-12, selecting the option to reset IP and Ethernet
Connecting to the web management interface
Table
7-7.
7-7