Connect To The Network - Motorola PTP 800 User Manual

Licensed ethernet microwave
Table of Contents

Advertisement

User Guide: PTP 800 Licensed Ethernet Microwave

Connect to the network

Perform this task to connect the CMUs to the network. There are two alternative
connection procedures:
x
One for out-of-band or out-of-band local management.
x
One for in-band management.
Out-of-band management
If the CMUs have been configured for out-of-band or out-of-band local management
mode, proceed as follows:
Procedure 5-26 Connect to network – out-of-band management
Disconnect the local PC from the CMU management port at each CMU.
1
At each CMU, connect the CMU Management port to a router port, switch
2
port or other network equipment in the management network. At the edge of
a network, it is possible that no network equipment will be reached through
the CMU, and in this case the CMU management port may be left
disconnected.
Check that each of the CMUs is reachable from the network management
3
system by opening the web interface to the management agents, or by
requesting ICMP echo response packets using the Ping application. The
network management system will normally be geographically remote from
the site, so it may be necessary to request that this action is completed by
co-workers at the management centre. Alternatively, it may be possible to
use remote login to the management system.
At each CMU, connect the CMU Data ports to a router port, switch port or
4
other network equipment in the customer data network using Ethernet
copper or fiber cable as appropriate.
Check the data network for correct operation across the wireless link. This
5
may be by requesting ICMP echo response packets between hosts in the
connected network segments, or by some more structured use of network
testing tools.
phn-1478_005v000
Apr 2010
Connecting the CMU to the network
5-111