B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 15 of 34)
ADDR
REGISTER NAME
5890
...Repeated for module number 19
5898
...Repeated for module number 20
58A0
...Repeated for module number 21
58A8
...Repeated for module number 22
58B0
...Repeated for module number 23
B
58B8
...Repeated for module number 24
58C0
...Repeated for module number 25
58C8
...Repeated for module number 26
58D0
...Repeated for module number 27
58D8
...Repeated for module number 28
58E0
...Repeated for module number 29
58E8
...Repeated for module number 30
58F0
...Repeated for module number 31
58F8
...Repeated for module number 32
Phase TOC (Read/Write Grouped Setting) (6 modules)
5900
Phase TOC Function
5901
Phase TOC Signal Source
5902
Phase TOC Input
5903
Phase TOC Pickup
5904
Phase TOC Curve
5905
Phase TOC Multiplier
5906
Phase TOC Reset
5907
Phase TOC Voltage Restraint
5908
Phase TOC Block For Each Phase (3 items)
590B
Phase TOC Target
590C
Phase TOC Events
590D
Reserved (3 items)
5910
...Repeated for module number 2
5920
...Repeated for module number 3
5930
...Repeated for module number 4
5940
...Repeated for module number 5
5950
...Repeated for module number 6
Phase Instantaneous Overcurrent (Read/Write Grouped Setting) (12 modules)
5A00
Phase Instantaneous Overcurrent 1 Function
5A01
Phase Instantaneous Overcurrent 1 Signal Source
5A02
Phase Instantaneous Overcurrent 1 Pickup
5A03
Phase Instantaneous Overcurrent 1 Delay
5A04
Phase Instantaneous Overcurrent 1 Reset Delay
5A05
Phase Inst OC 1 Block for each phase (3 items)
5A08
Phase Instantaneous Overcurrent 1 Target
5A09
Phase Instantaneous Overcurrent 1 Events
5A0A
Reserved (6 items)
5A10
...Repeated for module number 2
5A20
...Repeated for module number 3
5A30
...Repeated for module number 4
5A40
...Repeated for module number 5
5A50
...Repeated for module number 6
5A60
...Repeated for module number 7
5A70
...Repeated for module number 8
5A80
...Repeated for module number 9
5A90
...Repeated for module number 10
5AA0
...Repeated for module number 11
5AB0
...Repeated for module number 12
B-22
RANGE
0 to 1
0 to 5
0 to 1
0 to 30
0 to 16
0 to 600
0 to 1
0 to 1
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 30
0 to 600
0 to 600
0 to 65535
0 to 2
0 to 1
0 to 1
T60 Transformer Management Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F167
---
1
F122
pu
0.001
F001
---
1
F103
0 (IEEE Mod Inv)
---
0.01
F001
---
1
F104
0 (Instantaneous)
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
pu
0.001
F001
s
0.01
F001
s
0.01
F001
---
1
F300
---
1
F109
---
1
F102
---
1
F001
DEFAULT
0 (Disabled)
0 (SRC 1)
0 (Phasor)
1000
100
0 (Disabled)
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
1000
0
0
0
0 (Self-reset)
0 (Disabled)
0