GE t60 Instruction Manual page 283

Ur series transformer management relay
Hide thumbs Also See for t60:
Table of Contents

Advertisement

APPENDIX B
Table B–9: MODBUS MEMORY MAP (Sheet 10 of 34)
ADDR
REGISTER NAME
4086
RS485 Com2 Parity
4087
IP Address
4089
IP Subnet Mask
408B
Gateway IP Address
408D
Network Address NSAP
4097
Default GOOSE Update Time
409A
DNP Port
409B
DNP Address
409C
DNP Client Addresses (2 items)
40A0
TCP Port Number for the Modbus protocol
40A1
TCP/UDP Port Number for the DNP Protocol
40A2
TCP Port Number for the UCA/MMS Protocol
40A3
TCP Port Number for the HTTP (Web Server) Protocol
40A4
Main UDP Port Number for the TFTP Protocol
40A5
Data Transfer UDP Port Numbers for the TFTP Protocol
(zero means "automatic") (2 items)
40A7
DNP Unsolicited Responses Function
40A8
DNP Unsolicited Responses Timeout
40A9
DNP Unsolicited Responses Max Retries
40AA
DNP Unsolicited Responses Destination Address
40AB
Ethernet Operation Mode
40AC
DNP User Map Function
40AD
DNP Number of Sources used in Analog points list
40AE
DNP Current Scale Factor
40AF
DNP Voltage Scale Factor
40B0
DNP Power Scale Factor
40B1
DNP Energy Scale Factor
40B2
DNP Other Scale Factor
40B3
DNP Current Default Deadband
40B4
DNP Voltage Default Deadband
40B5
DNP Power Default Deadband
40B6
DNP Energy Default Deadband
40B7
DNP Other Default Deadband
40B8
DNP IIN Time Sync Bit Period
40B9
DNP Message Fragment Size
40BA
DNP Client Address 3
40BC
DNP Client Address 4
40BE
DNP Client Address 5
40C0
DNP Communications Reserved (8 items)
40C8
UCA Logical Device Name
40D0
GOOSE Function
40D1
UCA GLOBE.ST.LocRemDS Flexlogic Operand
40D2
UCA Communications Reserved (14 items)
40E0
TCP Port Number for the IEC 60870-5-104 Protocol
40E1
IEC 60870-5-104 Protocol Function
40E2
IEC 60870-5-104 Protocol Common Address of ASDU
40E3
IEC 60870-5-104 Protocol Cyclic Data Tx Period
40E4
IEC Number of Sources used in M_ME_NC_1 point list
40E5
IEC Current Default Threshold
40E6
IEC Voltage Default Threshold
40E7
IEC Power Default Threshold
40E8
IEC Energy Default Threshold
40E9
IEC Other Default Threshold
40EA
IEC Communications Reserved (22 items)
GE Multilin
RANGE
0 to 2
0 to 4294967295
0 to 4294967295
0 to 4294967295
---
1 to 60
0 to 4
0 to 65519
0 to 4294967295
1 to 65535
1 to 65535
1 to 65535
1 to 65535
1 to 65535
0 to 65535
0 to 1
0 to 60
1 to 255
0 to 65519
0 to 1
0 to 1
1 to 6
0 to 8
0 to 8
0 to 8
0 to 8
0 to 8
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
1 to 10080
30 to 2048
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
---
0 to 1
0 to 65535
0 to 1
1 to 65535
0 to 1
0 to 65535
1 to 65535
1 to 6
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1
T60 Transformer Management Relay
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F113
---
1
F003
---
1
F003
---
1
F003
---
---
F074
s
1
F001
---
1
F177
---
1
F001
---
1
F003
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F102
s
1
F001
---
1
F001
---
1
F001
---
1
F192
---
1
F102
---
1
F001
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F194
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
min
1
F001
---
1
F001
---
1
F003
---
1
F003
---
1
F003
---
1
F001
---
---
F203
---
1
F102
---
1
F300
---
1
F001
---
1
F001
---
1
F102
---
1
F001
s
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
---
1
F001
DEFAULT
0 (None)
56554706
4294966272
56554497
0
B
60
0 (NONE)
1
0
502
20000
102
80
69
0
0 (Disabled)
5
10
1
0 (Half-Duplex)
0 (Disabled)
1
2 (1)
2 (1)
2 (1)
2 (1)
2 (1)
30000
30000
30000
30000
30000
1440
240
0
0
0
0
"UCADevice"
1 (Enabled)
0
0
2404
0 (Disabled)
0
60
1
30000
30000
30000
30000
30000
0
B-17

Advertisement

Table of Contents
loading

Table of Contents