ELECTRICAL

Starter Solenoid Bench Test

Test the start solenoid by powering the solenoid using
battery voltage for a maximum of 5 seconds. With the
solenoid energized, resistance should read about 0 - 0.5
ohms between terminals (A) and (B). If resistance
measurement is out of specification, replace the starter
solenoid.
11.40
9925724 R01 - 2014-2015 RZR XP 1000 / RZR XP4 1000 Service Manual
© Copyright 2014 Polaris Industries Inc.

Starter Solenoid Operation

To energize the Starter Solenoid the following must
occur:
• The brake must be applied to provide a ground
path via the Orange wire.
• The key switch must be turned to the "start"
position to provide 12V power via the Green /
White wire.
• Once the pull-in coil is energized, the solenoid
provides a current path for 12V power to reach the
starter motor.
NOTE:
See
BREAOUTS: Starter-Interlock" provided in this
chapter for starter solenoid operation.
Condition: Starter fails to turn over the
engine.
"ELECTRICAL
SYSTEM