User Interface

5.1.2 Setting Keypad Display Values

The display area is activated when the adjustable
frequency drive receives power from AC line voltage, a DC
bus terminal, or an external 24 V supply.
The information displayed on the Keypad can be
customized for user application.
Each display readout has a parameter associated
with it.
Options are selected in main menu K-2#
The adjustable frequency drive status at the
bottom line of the display is generated automat-
ically and is not selectable.
Display
Parameter number
1.1
K-20
1.2
K-21
1.3
K-22
2 2.7
K-23
3
K-24

5.1.3 Display Menu Keys

Menu keys are used for menu access for parameter set-up,
toggling through status display modes during normal
operation, and viewing fault log data.
AF-650 GP Quick Guide
Key
Status
Quick Menu
Default setting
Speed [RPM]
Motor Current
Power [kW] [HP]
Frequency
Reference [%]
Main Menu
Alarm Log

5.1.4 Navigation Keys

Navigation keys are used for programming functions and
moving the display cursor. The navigation keys also
provide speed control in local (hand) operation. Three
drive status indicator lights are also located in this area.
DET-759A
Function
Press to show operational information.
Press repeatedly to scroll through each
status display.
Press and hold [Status] plus [
adjust the display brightness
The symbol in the upper right corner of the
display shows the direction of motor
rotation and which set-up is active. This is
not programmable.
Allows access to programming parameters for
initial set-up instructions and many detailed
application instructions.
Press to access Quick Start for sequenced
instructions to program the basic frequency
controller set up
Press to access Trending for realtime logging
on the keypad display.
Press to access Parameter Data Check for
changes in the parameter data set.
Follow the sequence of parameters as
presented for the function set-up
Allows access to all programming parameters.
Press twice to access top level index.
Press once to return to the last location
accessed.
Press and hold to enter a parameter
number for direct access to that parameter.
Displays a list of current warnings, the last 10
alarms, and the maintenance log.
For details about the adjustable frequency
drive before it entered the alarm mode,
select the alarm number using the
navigation keys and press [OK].
] or [
] to
5
5
21