HP HSR6800 Installation Manual page 39

Hide thumbs Also See for HSR6800:
Table of Contents

Advertisement

Figure 38 Connecting an E1 75-ohm cable
If you want to extend the cable, connect each BNC connector of the E1 75-ohm cable to one end
of a coaxial connector, and connect the remote device to the other end of the coaxial connector
through an E1 75-ohm adapter cable.
Figure 39 Connecting an E1 75-ohm cable
If the impedance of the E1 interface on the remote device is 120 ohms, you must use an impedance
converter to adapt the impedance.
Figure 40 Connecting an impedance converter
E1 / E1-F
(75ohm)
Connecting a T1 cable
1.
Connect the D68 connector of the 8-port T1 cable to the D68 interface on the interface module and
fasten the bolts to fix the cable.
E1 75-ohm cable
RX
TX
Impedance converter
Straight-through cable
33
Device
(120ohm E1 Port)