Control Configuration Level - ABB COMMANDER 1900 Series Programming Manual

Circular chart recorders
Hide thumbs Also See for COMMANDER 1900 Series:
Table of Contents

Advertisement

4 CONTROL CONFIGURATION LEVEL

OPrtOr
LEVEL
Operator Level
bASIC
CONFIG
Basic Config
CONtrL
CONFIG
Control Config
AdVNCd
CONFIG
Advanced Config
Set Points Page
Valve Page
Section 4.1, Page 29
Section 4.2.3, Page 35
SEt
VALVE
POINtS
PAGE
Set Points
Valve Page
SELECt
SELECt
––––––
––––––
Select Controller
Select Controller
LSP–HI
rAtIO
––––
–. – –
Set Point High Limit
M. Valve Ratio
LSP–LO
bIAS
––––
–. – –
Set Point Low Limit
M. Valve Bias
LSPt-x
rGL–t
––––
––––
Local Set Point
Regulator Travel
SP–trK
dEAd b
––––––
––. –
Set Point Tracking
M. Valve Deadband
2Nd–SP
 ––––
2nd Set Point
dSP–HI
––––
Dual S/P High Limit
dSP–LO
––––
Dual S/P Low Limit
dSPt-x
––––
Dual S/P Value
rSPtrK
_ _ _ _
Remote SP Tracking
rSP–HI
––––
Remote S/P High
rSP–LO
––––
Remote S/P Low
OP trK
_ _ _ _
Output Tracking
CAStrK
rAtIO
_ _ _ _
––––
Cascade SP Tracking
Ratio
CAS–HI
bIAS
––––
––––
Cascade S/P High
Bias
CAS–LO
------
––––
------
Cascade S/P Low
Set Point Type
Fig. 4.1 Control Configuration Level
Set Up Control Page
Operating Page Set Up
Section 4.3.1, Page 36
Section 4.4, Page 44
SEtUP
SEtUP
ContrL
OP PGE
Set Up Control
Set up Op Page
SELECt
SELECt
––––––
––––––
Select Controller
Select Controller
C-tYPE
INCMNt
––––
__
Control Type
Bargraph Increment
PFMOdE
PF–INd
––––––
–––
Power Failure Mode
Power Fail Enable
MAN . M AN
AUt_AN
–––. –
–––
Man/Man Power Fail
A/M Enable
AUt . M AN
_r_AdJ
–––
–––
Auto/Man Power Fail
Man. Reset Enab.
AUt . A Ut
SP–SEL
––––
–––
Auto/Auto PowerFail
S.P. Select Enable
MAN . A Ut
SP–AdJ
––. –
–––
Man/Auto Power Fail
S.P Adjust Enable
OFFSEt
r–ADJ
––. –
–––
Control Offset
Ratio Adjust Enable
b–AdJ
–––
ACtION
Bias Adjust Enable
–––
Control Action
Heat/Cool Control
OP–HI
–––. –
ACtION
Output High LImit
OP–LO
h –––
––––
Control Action High
Ht–HI
Output Low Limit
––––
dFA–PV
Heat High LImit
ACtION
––––
Default Action PV
C –––
dEF–OP
Control Action Cool
CL– ––
––––
Default Output
––––
dFA–SP
Cool High/Low Limit
––––
Default Action SP
dEF–SP
––––
Default SP
dFA–Fb
––––
Default Action PFB
Set Up Digital
Section 4.5, Page 45
SEtUP
dIGtAL
Set Up Digital
SELECt
––––––
Select Controller
A_ SrC
––––––
A/M Select Source
_AN . S rC
––––––
Man Select Source
C–OUt
––––––
Configured Output
AUt . S rC
––––––
Auto Select Source
Lr SrC
––––––
L/R Select Source
LOC . S rC
––––––
Local Select Source
rEM . S rC
––––––
Rmt Select Source
SP1 . S rC
––––––
Set Point 1 Source
SPt–1
––––
Set Point 1
SP2 . S rC
––––––
Set Point 2 Source
SPt–2
––––
Set Point 2
SP3 . S rC
––––––
Set Point 3 Source
SPt–3
––––
Set Point 3
27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents