Toro 30411 Operator's Manual page 42

Traction unit
Hide thumbs Also See for 30411:
Table of Contents

Advertisement

Test Port "B" (Fig. 57), located on the right side of the
machine, is used to measure the reverse traction pressure.
1
Figure 57
1. Test port "B"
Test Port "C" (Fig. 58), located on the left side of the
machine, is used to measure the left cutting unit pressure.
Figure 58
1. Test port "C"
Test Port "D" (Fig. 59), located on the right side of the
machine, is used to measure the right cutting unit pressure.
Figure 59
1. Test port "D"
1
1
Test Port "E" (Fig. 60), located under the radiator, is used
to measure the four-wheel drive pressure in reverse.
1. Test port "E"
Test Port "F" (Fig. 61), located under the seat, is used to
measure the lift circuit pressure.
Test Port "G" (Fig. 61), located under the seat, is used to
measure the charge circuit pressure.
1
1. Test port "F"
Test Port "H" (Fig. 62) is used to measure the center cutting
unit circuit pressure.
Test Port "J" (Fig. 62) is used to measure the steering
circuit pressure.
42
1
Figure 60
2
Figure 61
2. Test port "G"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 4100-d

Table of Contents