33.12.4 MII Serial Management Channel Timing

(EMDIO and EMDC)
The FEC functions correctly with a maximum MDC frequency of 2.5 MHz.
Table 33-20 lists MII serial management channel timings.
Table 33-20. MII Serial Management Channel Timing
Num
M10
EMDC falling edge to EMDIO output invalid (minimum propagation
delay)
M11
EMDC falling edge to EMDIO output valid (max prop delay)
M12
EMDIO (input) to EMDC rising edge setup
M13
EMDIO (input) to EMDC rising edge hold
M14
EMDC pulse width high
M15
EMDC pulse width low
Figure 33-13 shows MII serial management channel timings listed in Table 33-20.
EMDC (output)
EMDIO (output)
EMDIO (input)
Figure 33-13. MII Serial Management Channel Timing Diagram
MOTOROLA
Characteristic
M14
M12
M13
Chapter 33. Electrical Characteristics
Fast Ethernet AC Timing Specifications
Min
Max
0
25
10
0
40% 60% MDC period
40% 60% MDC period
M15
M10
M11
Unit
ns
ns
ns
ns
33-23