Leak Detector Alarm And Delay Timer - Toro Greensmaster 3150 Service Manual

Hide thumbs Also See for Greensmaster 3150:
Table of Contents

Advertisement

Leak Detector Alarm and Delay Timer

The leak detector alarm is used to notify the operator
that a hydraulic leak has occurred. To prevent the leak
detector system from sounding false alarms during nor-
mal operation, the alarm circuit includes a one (1) sec-
ond delay timer.
NOTE: For information on leak detector operation refer
to Turf Guardiant Leak Detector System Operation in
this chapter.
Testing
2
1
1. Park machine on a level surface. Make sure the en-
gine and ignition switch are OFF.
2. Turn ignition switch to the RUN position (do not start
the engine), then move leak detector test switch rear-
ward and hold. After a one (1) second time delay, the
alarm should sound.
Figure 31
1. Alarm
2. Delay timer
Greensmaster 3150