Time Setting / Time Display; Drawer Open Test - Casio QT-6100 Service Manual

Hide thumbs Also See for QT-6100:
Table of Contents

Advertisement

[ 20 ] Time setting / [ 21 ] Time display
[Function]
This sets the time and date.
When setting the time, the time and date will be displayed without inputting the fixed value.
[Operation]
* Date and time setting
Operation : x1 x2 x3 x4 x5 x6
a: 0: time setting x1/x2: time, x3/x4: minutes, x5/x6: second
1: time setting x1/x2: year, x3/x4: month, x5/x6: day
The test will be done one time.
* Date and time display
Operation :
7
To stop the operation, press "ESC" key.
[LCD]
DATE/TIME
70
DATE/TIME
YY/MM/DD HH:MM-SS
END
70
[PRINT]
DATE/TIME
YYMMDD0170
DATE
YY/MM/DD
END
YYMMDD0170

[ 22 ] Drawer open test

[Function]
This test will check the drawer open function. The test ends by the judgment of the operator ei-
ther by OK or NG only when the one time check is selected.
[Operation]
Operation :
x
x: 0 = All drawers open (can be omitted), 1 = Drawer 1 open, 2 = Drawer 2 open
n: 0 = One time check (can be omitted)
not 0 = Continuous check (To stop the test, press "ESC" key)
* When the continuous check is selected, the drawer opens every 2 seconds.
* The following "OK" or "NG" key can be used in case of one time check.
"OK" = 1, "NG" = 9
[LCD]
The status signal from the drawers appears in the status display position of the LCD.
In case of continuous check as well as when all drawers are open, the status appears after all
the drawers open.
DRW
xn091
DRW ALL
OK
END
xn091
0
0
ST
Each data will be printed only when setting the date and time.
n
0
9
1
ST
— 43 —
a
7
0
ST
[PRINT]
DRW
xn091
DRW ALL
OK
END
xn091

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents