4. ASSEMBLY

■ QT-6100
The photos show a similar model, QT-6000. Therefore the appearance may slightly differ.
▪ The number of COM ports has been changed from 6 to 3.
▪ The speaker has been deleted, and a buzzer has been added on the E819-S1 board.
1. Place the LCD UNIT in the frame and fix it with four screws.
2. Connect the connector and fix the inverter PCB with two screws.
3. Fix the LCD UNIT to the FRONT CASE with 14 screws.
Screw × 2
Fix the screws from above the earth plate.
Bind the wirings for the inverter.
— 15 —