► Error Code
A1–2311
A1–2312
A1–2313
► Error message
Motor Failure: #A1-2311. Turn off then on. Call for service if the problem persists
Motor Failure: #A1-2312. Turn off then on. Call for service if the problem persists
Motor Failure: #A1-2313. Turn off then on. Call for service if the problem persists
► Symptom
Magenta OPC motor operation is abnormal.
► Troubleshooting method
•
A1–2311 : Magenta OPC motor is stopped but machine recognizes it as operational.
•
A1–2312 : Magenta OPC motor is not operated for print-job.
•
A1–2313 : Magenta OPC motor is operating but machine recognizes status as "Stopped".
1) Turn the machine off then on. If the error persists, turn the machine off again.
2) Open the front cover. Check if there are any foreign substances or paper around magenta drum drive unit.
3) Turn the machine on. If the error persists, turn the machine off again.
4) Remove the rear cover after removing 7 screws.
5) Check if the magenta OPC motor connector is connected correctly.
6) If the connection is OK, turn the machine on. Enter SVC mode. Select magenta OPC motor test.
(Diagnostics > Engine Diagnostics > Engine Test Routines > 100–0042)
Check the motor operation.
a) If the motor is not operational,
Copyright© 1995-2013 SAMSUNG. All rights reserved.
4. Troubleshooting
4-92