(d) GAMMA select buttons and display window
Select the step gamma. The selected value is displayed in the
window. The gamma value decreases when the
pressed and increases when the
continuously changes while either button remains pressed.
Note The higher the gamma effect, the lower the value.
(e) MASTER GAIN select buttons and display window
Select the appropriate video gain according to the illumination of the
subject to be shot. The selected value (dB) is displayed in the
window. The gain value increases when the
and decreases when the
(down) button is pressed. It continuously
changes either button remains pressed.
17) IRIS/MB ACTIVE (iris/master black active) button
Press and illuminate this button to enable the iris and master black
adjustment functions of this unit. When the PANEL ACTIVE button
is pressed, this button automatically illuminates. To disable only the
iris/master black control block of the panel, press this button so that
it is not illuminated.
18) MASTER BLACK control block
Turn the control to adjust the master black level. The adjustment
value is displayed in the display window.
19) CALL button
Press to send a call signal to the camera, on which the CALL button
is illuminated. The tally lamps on the camera and the red tally lamp
on the CCU-700A/700AP light if they not illuminated, or are turned
off if they where illuminated. When the CALL button on the camera
is pressed, the CALL button on this unit illuminates and a buzzer
sounds.
20) Camera number/tally indication window
The number of the camera being controlled from this unit is
displayed in orange. When a red tally signal is sent to the camera, its
number is displayed in black against a red background. When a
Connector Panel
1
FUSE holder
FUSE
1) FUSE holder
Accommodates the fuse.
2) POWER switch
Turns the power to the unit on and off.
3) ~AC IN (AC power input) connector
Connect to an AC power source using the supplied AC power cord.
The power cord can be fixed to this unit using the supplied plug
holder.
4) CCU/CNU REMOTE (camera control unit/camera command
network unit remote) connector (8-pin)
(up) button is
(down) button is pressed. It
(up) button is pressed
2
POWER switch
3
~AC IN connector
POWER
~AUX IN
Location and Function of Parts and Controls
green tally signal is sent to the camera, its number is displayed in
black against a green background. When both the red and green
tally signals are sent simultaneously, the left half of the background
is red and the right half is green.
21) Iris control block
a
EXT
b
(a) EXT (lens extender) indicator
Illuminated when the lens extender is in use.
(b) IRIS control and display window
When the AUTO button is not illuminated, you can adjust the iris
manually by turning this control. The adjustment value is shown in f
numbers on the display. When the AUTO button is illuminated, the
reference value for automatic iris adjustment can be set in a range of
+/-1f stop with this control. When the iris is closed, 'CL' is displayed
in the window.
(c) AUTO button
Press and illuminate the button and the iris automatically adjusts to
the amount of input light. If you press the button when it is
illuminated, the illumination is turned off and manual iris adjustment
is enabled.
4
CCU/CNU REMOTE connector
5
AUX REMOTE connector
REMOTE
CCU/CNU
AUX
I/O PORT
6
I/O PORT connector
Connect to the RCP/CNU connector of the CCU-700A/700AP or the
MSU connector of the CNU-700.
5) AUX REMOTE (auxiliary remote) connector (8-pin)
6) I/O PORT connector (50-pin)
Reserved for future use.