Sony BVP-900 Series Product Information Manual page 74

Studio/ob/efp camera family
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

10
Location and Function of Parts and Controls
15) RCP/CNU REMOTE (remote control panel/camera command
network unit /remote control connector (8-pin)
Connect an MSU-700, CNU-700, CNU-500 or RCP-700 Series Remote
Control Panel using a CCA-5 cable. Control signals are then
accepted. When an RCP-700 Series panel is connected, power is also
supplied to the unit.
16) AUX (auxiliary) REMOTE connector (8-pin)
Connection for an external system. For details on connections, refer
to an authorized Sony representative.
17) SERIAL OUTPUT 1, 2 and 3 (serial digital video signal 1, 2
and 3 output) connectors (BNC type)
Camera output serial digital video signals are available from these
connectors when an optional BKP-7311 SDI output board is installed
in the CCU. The outputs from these connectors provide signals to a
digital video switcher, component digital VTR, etc.
18) SERIAL INPUT RET 1 AND RET 2 (serial digital video signal 1
and 2 output) connectors (BNC type)
These connectors accept 10-bit, 4:2:2 component serial digital video
signals as return video 1 and 2 signals. They function when an
optional BKP-7312 SDI input board is installed in the CCU. When
this BKP-7312 is installed, the RET 1 and RET 2 connectors in the
ANALOG INPUT block are disabled.
19) Spare connectors (BNC type)
20) COAX (coaxial) connector (BNC type)
Accepts and supplies the signals normally carried by a triax cable,
except for power, by setting a switch on the internal DM board. For
connection, use a coaxial cable. When a return video function is
used, the maximum cable length of a 5C-2V (RG-6A/U) coaxial cable
is 800 m (2,624 feet). With the optional long distance board installed,
the maximum cable length is increased to 1,000 m (3,280 feet).
21) INTERCOM/TALLY/PGM (program audio) connector (19-pin)
Supplies and accepts intercom, tally and program audio signals.
Connect to the corresponding connector on the intercom system.
22) RTS (RTS intercom) connectors (XLR 3-pin)
Connection for an RTS intercom system.
23) INTERCOM REMOTE connector (D-sub 25-pin)
Connection for an external controller to control intercom muting,
producer line interruption and engineer line interruption. This
connector outputs the red tally, green tally, call signals and camera
number.
24) MIC REMOTE (microphone remote control) connector (D-sub
15-pin)
Connection for an external control unit, from which the microphone
input levels of the camera can be set to -60, -50, -40, -30 or -20 dB. You
can also set these microphone input levels with the switch on the
internal board of the CCU. This connector outputs the red tally and
green tally signals. For details on setting the microphone input levels
with the internal switch, refer to the system manual.
25) Voltage selector (CCU-700AP only)
The operating voltage of the CCU-700AP is factory set to 220 to 240
V AC. If the voltage of your local power line is different, contact Sony
service personnel to change the voltage selector setting.