Locating The Defective System Unit; Determining The Error Class - Fujitsu Primergy BX900 S2 Upgrade And Maintenance Manual

System unit
Hide thumbs Also See for Primergy BX900 S2:
Table of Contents

Advertisement

Ê Connect the FST to the serial port of the management blade (3)
and open a terminal session, see the "PRIMERGY BX900 Blade
Server Systems ServerView Management Blade S1 User
Interface Description".
Ê Open the Management Agent – Management Agent Information menu
to view the Management Agent Administrative URL.
Ê Login to the management blade web interface as described
above.
4.1.2

Locating the defective system unit

When working in a datacenter environment, switch on the ID indicator on the
front and rear of the system unit (see section
page
179) for easy identification.
Ê Press the ID button on the Local Service Display or on the management
blade or use the ServerView Operations Manager or the management blade
web interface, to switch on the ID indicators.
Ê When using ServerView Operations Manager to toggle the ID indicator,
choose Single System View and press the Locate button.
Ê When using the management blade web interface to toggle the ID indicator,
press the Locate button in the status frame.
Ê Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.3

Determining the error class

Customer Replaceable Units (CRU)
Failure events are assigned to one of two error classes:
– Global Error events that need to be resolved by maintenance personnel
– Customer Self Service (CSS) error events that may be resolved by
operating personnel
BX900 S2
Upgrade and Maintenance Manual
Basic hardware procedures
"Connectors and indicators" on
45