Specifications
Model Numbers Covered in this Specification
CD963
Gas Griddle 610mm wide Bench Model.
CD964
Gas Griddle 915mm wide Bench Model.
General
A commercial heavy duty, fully modular, gas fired griddle using a thermostatic burner system and
fitted with stainless steel burners with full pilot and flame failure protection and piezo ignition.
It uses a 19mm thick griddle smooth plate
Pack Contents
The following is included:
BUFFALO Gas Griddle
Regulator
Feet
Instruction Manual
Gas Supply Requirements
Natural Gas (G20)
CD963
Heat Input (nett)
14 Kw
1.45 m
Gas Rate (nett)
20mbar
Supply Pressure
Burner Operating
15mbar
Pressure
Gas Connection
The burner operating pressure is to be measured at the gas control valve outlet test point withone griddle
burner operating at „High‟ setting. The operating pressure is ex-factory set, through the appliance regulator
and not to be adjusted, apart from when carrying out gas conversion, if required.
Conversion‟ section for details).
Natural gas(G25)
CD964
CD963
21 Kw
14 Kw
3
3
2.2 m
1.7 m
/hr
/hr
25mbar
15mbar
CD964
21 Kw
3
3
2.5 m
/hr
/hr
¾" BSP Male
3
Propane(G31)
CD963
CD964
14 Kw
21 Kw
1100 g/hr
1630 g/hr
37&50mbar
25mbar
(Refer to the „Gas